HSG80 ACS Solution Software Version 8.7 for Compaq OpenVMS Installation and Configuration Guide
FC Configuration Procedures
5–17HSG80 ACS Solution Software Version 8.7 for Compaq OpenVMS Installation and
Configuration Guide
5–17
Verify Installation
To verify installation for your OpenVMS host, enter the following command:
SHOW DEVICES
Your host computer should report that it sees a device whose designation matches the
identifier (CCL) that you assigned the controllers. For example, if you assigned an
identifier of 88, your host computer will see device $1$GGA88. This verifies that
your host computer is communicating with the controller pair.
Configuring Devices
The disks on the device bus of the HSG80 can be configured manually or with the
CONFIG utility. The CONFIG utility is easier. Invoke CONFIG with the following
command:
RUN CONFIG
WARNING: It is highly recommended to use the CONFIG utility only at reduced
I/O loads.
CONFIG takes about two minutes to discover and to map the configuration of a
completely populated storage system.
Configuring Storage Containers
For a technology refresher on this subject, refer to “Choosing a Container Type,” page
2–14.
In choosing a container, you choose between independent disks (JBODs) or one of
several storageset types, as shown in Figure 5–4. The independent disks and the
selected storageset may also be partitioned.
The following configurations are detailed in the following section:
• “Configuring a Stripeset” on page 5–18
• “Configuring a Mirrorset” on page 5–19
• “Configuring a RAIDset” on page 5–20
• “Configuring a Striped Mirrorset” on page 5–20