HSG80 ACS Solution Software Version 8.7 for Compaq OpenVMS Installation and Configuration Guide
FC Configuration Procedures
5–14 HSG80 ACS Solution Software Version 8.7 for Compaq OpenVMS Installation and
Configuration Guide
When FRUTIL asks if you intend to replace the battery, answer “Y”:
Do you intend to replace this controller's cache battery? Y/N [N] Y
FRUTIL will print out a procedure, but will not give you a prompt. Ignore the
procedure and press Enter.
12. Set up any additional optional controller settings, such as changing the CLI
prompt. See the
SET THIS CONTROLLER/OTHER CONTROLLER command in the StorageWorks
HSG80 Array Controller ACS Version 8.7 CLI Reference Guide for the format of
optional settings. Perform this step on both controllers.
13. Verify that all commands have taken effect by entering the following command:
SHOW THIS