HSG80 ACS Solution Software Version 8.7 for Compaq OpenVMS Installation and Configuration Guide

FC Configuration Procedures
5–7HSG80 ACS Solution Software Version 8.7 for Compaq OpenVMS Installation and
Configuration Guide
5–7
When FRUTIL asks if you intend to replace the battery, answer “Y”:
Do you intend to replace this controller's cache battery? Y/N [N] Y
FRUTIL will print out a procedure, but will not give you a prompt. Ignore the
procedure and press the Enter key.
3. Set up any additional optional controller settings, such as changing the CLI
prompt. See the
SET THIS CONTROLLER/OTHER CONTROLLER command in the StorageWorks
HSG80 Array Controller ACS Version 8.7 CLI Reference Guide for the format of
optional settings.
4. Verify that all commands have taken effect. Use the following command:
SHOW THIS
Verify node ID, allocation class, SCSI version, failover mode, identifier, and port
topology.