HSG60 and HSG80 Controller and HSx80 Cache Module Replacement Procedures for Array Controller Software V8.7x-x Release Notes

Software Anomalies
59HP StorageWorks HSG60 and HSG80 Controller and HSx80 Cache Module Replacement
Procedures for Array Controller Software V8.7x-x Release Notes
Software Anomalies
This section describes software anomalies inherent in ACS V8.7, 8.7-1, and
V8.7-2.
LED Code 38
When installing a controller, FRUTIL output incorrectly states that the controller
halts with LED code 38. The controller actually halts with LED code 33.
Installing Both the Controller and Cache Module
FRUTIL allows you the option to install both controller and cache module.
However, HP recommends that you do not install both the controller and cache
module together. Install either the controller or cache module as separate
procedure, exiting FRUTIL after installing one of the two module.
NVRAM Cache Configuration
The Port #5 button reset does not clear NVRAM cache configuration
information. This anomaly causes numerous invalid cache and bugcheck faults.