HSG60 and HSG80 Controller and HSx80 Cache Module Replacement Procedures for Array Controller Software V8.7x-x Release Notes

Troubleshooting
51HP StorageWorks HSG60 and HSG80 Controller and HSx80 Cache Module Replacement
Procedures for Array Controller Software V8.7x-x Release Notes
Troubleshooting
This section provides instructions on resolving common problems that may occur
while replacing controllers or cache modules. This section covers the following
topics:
Resolving Invalid Cache Error Messages—Serial Number Mismatch Error
Messages, page 51
Resolving Failed Cache Error Messages, page 52
Resolving Unexpected Bugcheck Condition Error Messages, page 57
Resolving Invalid Cache Error Messages—Serial Number Mismatch
Error Messages
An invalid cache error message may display after the SHOW
THIS_CONTROLLER command is submitted. The controller reports that the
cache and mirrored cache with cache are invalid and that the cache should be
installed in a specific controller with the serial number ZGxxxxxxxx.
Caution: Failure to clear an invalid cache message (especially aCache is
FAILED” message)
before
setting the Failover mode can result in a recursive
bugcheck error message that renders the controller unusable.
To resolve an invalid cache error message, see Table 3 on page 52.