HSG60 and HSG80 Controller and HSx80 Cache Module Replacement Procedures for Array Controller Software V8.7x-x Release Notes
Troubleshooting
51HP StorageWorks HSG60 and HSG80 Controller and HSx80 Cache Module Replacement
Procedures for Array Controller Software V8.7x-x Release Notes
Troubleshooting
This section provides instructions on resolving common problems that may occur
while replacing controllers or cache modules. This section covers the following
topics:
■ Resolving Invalid Cache Error Messages—Serial Number Mismatch Error
Messages, page 51
■ Resolving Failed Cache Error Messages, page 52
■ Resolving Unexpected Bugcheck Condition Error Messages, page 57
Resolving Invalid Cache Error Messages—Serial Number Mismatch
Error Messages
An invalid cache error message may display after the SHOW
THIS_CONTROLLER command is submitted. The controller reports that the
cache and mirrored cache with cache are invalid and that the cache should be
installed in a specific controller with the serial number ZGxxxxxxxx.
Caution: Failure to clear an invalid cache message (especially a “Cache is
FAILED” message)
before
setting the Failover mode can result in a recursive
bugcheck error message that renders the controller unusable.
To resolve an invalid cache error message, see Table 3 on page 52.