HSG60 and HSG80 Controller and HSx80 Cache Module Replacement Procedures for Array Controller Software V8.7x-x Release Notes

What’s New
5HP StorageWorks HSG60 and HSG80 Controller and HSx80 Cache Module Replacement
Procedures for Array Controller Software V8.7x-x Release Notes
Whats New
These Release Notes address procedural enhancements for replacing any of the
following HP hardware devices that use ACS V8.7x-x. HP StorageWorks HSG80
controller.
HP StorageWorks HSG60 controller
HP StorageWorks HSx80 cache module
Note: The information in these Release Notes supersede all other HSG60 and HSG80
controller and HS
x
80 cache module replacement procedures, including procedures
detailed in the
HP StorageWorks HSG80 Array Controller V8.7 Maintenance and
Service Guide
.
Specific ACS version changes are summarized below:
ACS V8.7, V8.7-1, and V8.7-2 Changes
The program card must not be installed before the replacement controller
is inserted.
The controller Port #5 button must be pressed at the same time as the
controller Reset button when you insert the program card into its bay
during a new controller installation.
The baud rate for the replacement controller after it is installed now
changes to 19200 after a Port #5 button reset.
ACS V8.7-3 Changes
The program card must not be installed before the replacement controller
is inserted.
—The Port #5 button must be pressed at the same time as the Reset button
when you insert the program card into its bay during a new controller
installation.
—The Port #5 button reset clears the nonvolatile random access memory
(NVRAM) cache configuration information.
—The Field Replacement Utility (FRUTIL) output states that the halt LED
code is 33 appropriately.