HSG60 and HSG80 Controller and HSx80 Cache Module Replacement Procedures for Array Controller Software V8.7x-x Release Notes
Replacing HSx80 Cache Modules in Single and Dual-Redundant Controller Configurations
46 HP StorageWorks HSG60 and HSG80 Controller and HSx80 Cache Module Replacement
Procedures for Array Controller Software V8.7x-x Release Notes
Note: The controller connected to the PC or terminal becomes “this controller.” The
controller for the replacement cache module becomes the “other controller.”
b. Start FRUTIL by entering the following command:
RUN FRUTIL
c. Enter N(o) to the question about replacing the cache battery.
d. From the FRUTIL Main Menu, enter 2 for the Install a controller or
cache module option.
If both the controller and cache module are missing, the Install Options
screen is displayed.
Figure 18: Install Options screen (as displayed using ACS V8.7, V8.7-1, or V8.7-2)
Figure 19: Install Options Screen (as displayed using ACS V8.7-3)
e. Enter 3 to install the other cache module. The Slot Designations screen is
displayed.
f. Enter Y(es) to confirm the intent to install the slot x cache module.
Install Options:
1. Other controller and cache module
2. Other controller module
3. Other cache module
4. Exit
Enter choice: 1,2,3,4 ->
Install Options:
1. Other controller and cache module
2. Other controller module
3. Other cache module
4. Exit
NOTE: OPTION 1 DISABLED (So: Do cache, then controller.)
Enter choice: 1,2,3,4 ->