HSG60 and HSG80 Controller and HSx80 Cache Module Replacement Procedures for Array Controller Software V8.7x-x Release Notes

Replacing HSx80 Cache Modules in Single and Dual-Redundant Controller Configurations
40 HP StorageWorks HSG60 and HSG80 Controller and HSx80 Cache Module Replacement
Procedures for Array Controller Software V8.7x-x Release Notes
5. Restart the controller by pressing the Reset button.
Note: A controller restart can take as long as 60 seconds, indicated by the temporary
cycling of the port LEDs and a flashing Reset button.
Note: If the controller did not restart, use the following steps:
1. Press and hold the Reset button.
2. Reseat the controller program card.
3. Release the Reset button.
6. From the CLI prompt, display details about the configured controller by
entering the following command:
SHOW THIS_CONTROLLER FULL
7. Set the date and time by entering the following command:
SET THIS_CONTROLLER TIME=dd-mmm-yyyy:hh:mm:ss
8. Mount the logical units on the host.
9. If using a Windows 2000 or Windows NT platform, restart the server.
10. Disconnect the PC or terminal from the controller maintenance port.