HSG60 and HSG80 Controller and HSx80 Cache Module Replacement Procedures for Array Controller Software V8.7x-x Release Notes

Replacing HSx80 Cache Modules in Single and Dual-Redundant Controller Configurations
38 HP StorageWorks HSG60 and HSG80 Controller and HSx80 Cache Module Replacement
Procedures for Array Controller Software V8.7x-x Release Notes
Note: To facilitate pressing down on the DIMM retaining clips, consider using the
eraser end of a pencil or a small screwdriver.
a. Press down on the DIMM retaining clips (see Figure 17) at both ends of
the DIMM being removed.
b. Gently remove the DIMM from the DIMM slot, and place the DIMM on
an antistatic bag or a grounded antistatic mat.
c. Repeat substep 7a and substep 7b above for each DIMM.
d. Proceed to step 1 of “Installing HSx80 Cache Modules in Single
Controller Configurations” on page 39 to install the DIMMs in the
replacement cache module.
Figure 17: Removing or installing a DIMM
1 DIMM
2 DIMM slot
3 DIMM retaining clip
3
3
2
1