HSG60 and HSG80 Controller and HSx80 Cache Module Replacement Procedures for Array Controller Software V8.7x-x Release Notes

Replacing HSx80 Cache Modules in Single and Dual-Redundant Controller Configurations
34 HP StorageWorks HSG60 and HSG80 Controller and HSx80 Cache Module Replacement
Procedures for Array Controller Software V8.7x-x Release Notes
Replacing HS
x
80 Cache Modules in Single and
Dual-Redundant Controller Configurations
Replacing a cache module involves transferring the cache memory DIMMs from
the failed cache module to the replacement cache module. Use the procedures in
this section to replace a cache module in either single or dual-redundant controller
configurations.
Caution: With ACS V8.7, V8.7-1, and V8.7-2,
FRUTIL
allows you to install
both the controller and cache module in the same process. HP does not
recommend this. Replacing both the controller and cache module at the same
time can result in loss of controller configuration information and will render
the controller unusable.
Note: With ACS V8.7-3,
FRUTIL
prohibits you from installing both the controller and
cache module in one process.
This section contains the following topics:
Replacing HSx80 Cache Modules in Single Controller Configurations,
page 36
Replacing HSx80 Cache Modules in Dual-Redundant Controller
Configurations, page 41
Note: In dual-redundant configurations, both cache modules
must
contain the same