HSG60 and HSG80 Controller and HSx80 Cache Module Replacement Procedures for Array Controller Software V8.7x-x Release Notes

Replacing HSG60 and HSG80 Controllers in Single and Dual-Redundant Controller Configurations
33HP StorageWorks HSG60 and HSG80 Controller and HSx80 Cache Module Replacement
Procedures for Array Controller Software V8.7x-x Release Notes
The above commands copy the subsystem configuration from the
operational controller to the controller that failed or is being replaced.
c. Verify that the replacement controller restarts and that the cache for both
the operational and replacement controller is good by entering the
following command:
SHOW THIS_CONTROLLER
SHOW OTHER_CONTROLLER
Refer to Table 3 through Table 5, as applicable if the cache is not good.
Note: The replacement controller might fail with a recursive bugcheck (OCP code 25),
and the Reset button LED remains steady on. Contact HP technical support or replace
the controller if this condition occurs.
9. Disconnect the PC or terminal from the controller maintenance port of the
operational controller.
H 10. Connect the host bus cables to the replacement controller.
H 11. Install the program card ESD cover on the controller being replaced.