HSG60 and HSG80 Controller and HSx80 Cache Module Replacement Procedures for Array Controller Software V8.7x-x Release Notes
Replacing HSG60 and HSG80 Controllers in Single and Dual-Redundant Controller Configurations
32 HP StorageWorks HSG60 and HSG80 Controller and HSx80 Cache Module Replacement
Procedures for Array Controller Software V8.7x-x Release Notes
H c. Verify that the controller restarts in the following reset configuration by
entering the following command:
SHOW THIS_CONTROLLER
H — Verify that the controller prompt displays HSG>.
H — Verify that the NODE_ID is 0000-0000-0000-0000.
H — Verify that mirrored cache matches the original configuration.
H — Verify that the controller cache is good. Refer to Table 3 through
Table 5, as applicable if the cache is not good.
Caution: Failure to clear an invalid cache message (especially a “Cache is
FAILED” message) in
substep 7c
before
setting the Failover mode can result
in a recursive bugcheck condition that renders the controller unusable.
H d. Disconnect the PC or terminal from the maintenance port of the
replacement controller.
8. For the operational controller, complete the following substeps:
a. Connect a PC or terminal to the maintenance port of the operational
controller.
Caution: In substep 8b below, entering the appropriate SET command is
critical. Enabling an incorrect Failover mode can cause loss of data and incur
system down time.
b. Restore the Failover mode and re-establish the dual-redundant controller
configuration with one of the following commands. For example, if you
noted that the Failover mode in substep 1c on page 21 was Multibus, enter
the second command below.
SET FAILOVER COPY=THIS_CONTROLLER
or
SET MULTIBUS_FAILOVER COPY=THIS_CONTROLLER