HSG60 and HSG80 Controller and HSx80 Cache Module Replacement Procedures for Array Controller Software V8.7x-x Release Notes

Replacing HSG60 and HSG80 Controllers in Single and Dual-Redundant Controller Configurations
30 HP StorageWorks HSG60 and HSG80 Controller and HSx80 Cache Module Replacement
Procedures for Array Controller Software V8.7x-x Release Notes
H 5. For the replacement controller, complete the following substeps:
H a. Remove the program card in the replacement controller if it is installed.
H b. Insert the replacement controller (without the program card installed)
into the appropriate bay, and engage the controller retaining levers.
H c. Press and hold the Reset button, insert the program card, and continue
holding the Reset button.
H d. Press and hold the replacement controller Port #5 button, release the
Reset button, and continue holding the Port #5 button for an additional 5
to 20 seconds (see Figure 5 on page 16).
The nonvolatile memory in the replacement controller is updated, and the
controller halts with an LED code of 33. Port LEDs 1, 2, 5, and 6 are on
(see Figure 5 on page 16).
H e. Press and release the Reset button.
The replacement controller restarts normally.
H f. Wait at least 15 seconds after releasing the Reset button, and then
immediately complete substep 6a below. Be sure to wait 15 seconds
before continuing to substep 6a.
Note: A controller restart can take as long as 60 seconds, indicated by the temporary
cycling of the port LEDs and a flashing R
RR
Reset
eseteset
eset button.
6. For the operational controller, complete the following substeps:
a. Press Enter or Return within 3 minutes of completing substep 5f above
to exit FRUTIL, and then wait 1 minute to allow the replacement
controller to restart.