HSG60 and HSG80 Controller and HSx80 Cache Module Replacement Procedures for Array Controller Software V8.7x-x Release Notes

Replacing HSG60 and HSG80 Controllers in Single and Dual-Redundant Controller Configurations
29HP StorageWorks HSG60 and HSG80 Controller and HSx80 Cache Module Replacement
Procedures for Array Controller Software V8.7x-x Release Notes
Figure 14: Install Options Screen (as displayed using ACS V8.7-3)
f. Enter option 4 to exit FRUTIL, and then proceed to Installing an HSx80
Cache Module in Dual-Redundant Controller Configurations” on page 45
if both the controller and cache modules have been removed. Otherwise,
continue to the next substep.
g. Enter Y(es) to confirm the intent to install the “other controller.” FRUTIL
quiesces the device ports and displays a message indicating that the
controller is being installed.
Caution: Wait for
FRUTIL
to quiesce the device ports—indicated by an “All
device ports quiesced” message. Failure to allow the ports to quiesce
might result in data loss. Quiescing might take several minutes. The length of
time is dependent on the amount of I/O activity and the number of units that
are online.
Note: If you are using ACS V8.7, 8.7-1, 8.7-2,
FRUTIL
states that the replacement
controller OCP LED code is 38 and that port LEDs 1, 2, and 3 are on. However, the
actual OCP LED code should be 33 and port LEDs 1, 2, 5, and 6 should be on.
Note: If
FRUTIL
times out before a replacement controller is installed, restart
FRUTIL
.
\
Install Options:
1. Other controller and cache module
2. Other controller module
3. Other cache module
4. Exit
NOTE: OPTION 1 DISABLED (So: Do cache, then controller.)
Enter choice: 1,2,3,4 ->