HSG60 and HSG80 Controller and HSx80 Cache Module Replacement Procedures for Array Controller Software V8.7x-x Release Notes

Replacing HSG60 and HSG80 Controllers in Single and Dual-Redundant Controller Configurations
28 HP StorageWorks HSG60 and HSG80 Controller and HSx80 Cache Module Replacement
Procedures for Array Controller Software V8.7x-x Release Notes
4. For the operational controller, complete the following substeps:
a. Connect a PC or terminal to the maintenance port of the operational
controller if not already connected.
Note: The controller connected to the PC or terminal becomes “this controller.” The
controller being removed becomes the “other controller.
b. Ensure that the controller configuration is customized to your needs, and
then record the controller configurations (for example, Failover mode,
cache status, serial numbers, SCSI mode, mirrored/nonmirrored
information, and so forth).
c. Start FRUTIL by entering the following command:
RUN FRUTIL
d. Enter N(o) to the question about replacing the cache battery. The
FRUTIL Main Menu is displayed (see Figure 8 or Figure 9 on page 23).
e. Enter option 2 to install a controller or cache module.
If both the controller and cache are missing, the Install Options screen is
displayed (see Figure 13 or Figure 14):
Figure 13: Install Options screen (as displayed using ACS V8.7, V8.7-1, or V8.7-2)
Install Options:
1. Other controller and cache module
2. Other controller module
3. Other cache module
4. Exit