HSG60 and HSG80 Controller and HSx80 Cache Module Replacement Procedures for Array Controller Software V8.7x-x Release Notes
Replacing HSG60 and HSG80 Controllers in Single and Dual-Redundant Controller Configurations
27HP StorageWorks HSG60 and HSG80 Controller and HSx80 Cache Module Replacement
Procedures for Array Controller Software V8.7x-x Release Notes
H f. Press and hold the Port #5 button.
H g. Release the Reset button, while continuing to hold the Port #5
button, until the OCP LEDs read 33.
H 3. For the replacement controller, complete the following substeps to install and
remove ACS patches:
Note: In the following substeps, all nonapplicable patches are removed from the
replacement controller, and ACS V8.7-2 and V8.7-3 patches are applied.
H a. Locate and obtain the ACS V8.7-2 and V8.7-3 patches from the HP
website.
H b. Remove the unwanted patches by using Code-load Code-patch (CLCP)
as described in HP StorageWorks HSG80 Array Controller V8.7
Maintenance and Service Guide.
H c. Install the ACS V8.7-2 and V8.7-3 patches using the CLCP utility and
following the instructions described in HP StorageWorks HSG80 Array
Controller V8.7 Maintenance and Service Guide.
H d. Exit CLCP, and restart the replacement controller.
H e. Verify the replacement controller code version ACS V8.7-3 using the
following command:
SHOW THIS_CONTROLLER
H f. Shut down the replacement controller with the following command:
SHUTDOWN THIS_CONTROLLER
H g. Remove the program card from the replacement controller.
H h. Remove the replacement controller from the enclosure.
H i. Disconnect the PC or terminal from the replacement controller.