HSG60 and HSG80 Controller and HSx80 Cache Module Replacement Procedures for Array Controller Software V8.7x-x Release Notes
Replacing HSG60 and HSG80 Controllers in Single and Dual-Redundant Controller Configurations
24 HP StorageWorks HSG60 and HSG80 Controller and HSx80 Cache Module Replacement
Procedures for Array Controller Software V8.7x-x Release Notes
Figure 11: Slot Designations screen for controllers in a BA370 enclosure
Figure 12: Slot Designations screen for controllers in an M2100/M2200 enclosure
e. Make sure that the program card was removed from the controller to be
replaced. Do not proceed until it is removed.
f. Enter Y(es) to confirm the intent to remove the “other controller.”
Caution: Wait for
FRUTIL
to quiesce the device ports—indicated by an “All
device ports quiesced” message. Failure to allow the ports to quiesce
might result in data loss. Quiescing might take several minutes.
Note: After the ports quiesce, a countdown timer allows you a total of 2 minutes to
remove the controller. After 2 minutes, the operational controller exits
FRUTIL
and
resumes operations. If this happens, return to step 4 on page 22 and proceed.
Slot Designations (BA370)
(front view)
[ ---- EMU ---- ][ ---- PVA ---- ]
[ ---------- Controller A -------- ]
[ ---------- Controller B -------- ]
[ Cache Module A ] [ Cache Module B ]
Slot Designations M2100/M2200
(back view)
[ Port1 ] [ Port3 ] [ Port5 ]
[ Port2 ] [ Port4 ] [ Port6 ]
[ --------- Controller A -------- ]
[ --------- Controller B -------- ]
[ Cache Module A ] [ Cache Module B ]