HSG60 and HSG80 Controller and HSx80 Cache Module Replacement Procedures for Array Controller Software V8.7x-x Release Notes

Replacing HSG60 and HSG80 Controllers in Single and Dual-Redundant Controller Configurations
23HP StorageWorks HSG60 and HSG80 Controller and HSx80 Cache Module Replacement
Procedures for Array Controller Software V8.7x-x Release Notes
Figure 8: FRUTIL Main Menu for a controller in a BA370
Figure 9: FRUTIL Main Menu for a controller in a M2100/M2200 enclosure
c. Enter option 1 to remove the controller or cache module. The Replace or
remove Options screen is displayed (see Figure 10).
Figure 10: Replace or remove Options screen
d. Enter option 2 to remove the controller being replaced. The Slot
Designations screen is displayed (see Figure 11 or Figure 12, as
applicable).
FRUTIL Main Menu:
1. Replace or remove a controller or cache module
2. Install a controller or cache module
3. Replace a PVA module
4. Replace an I/O module
5. Exit
Enter choice: 1,2,3,4,5 ->
FRUTIL Main Menu
1. Replace or remove a controller or cache module
2. Install a controller or cache module
3. Replace an I/O module
4. Exit
Enter choice: 1,2,3,4 ->
Replace or remove Options:
1. Other controller and cache module
2. Other controller module
3. Other cache module
4. Exit
Enter choice: 1,2,3,4 ->