HSG60 and HSG80 Controller and HSx80 Cache Module Replacement Procedures for Array Controller Software V8.7x-x Release Notes

Replacing HSG60 and HSG80 Controllers in Single and Dual-Redundant Controller Configurations
21HP StorageWorks HSG60 and HSG80 Controller and HSx80 Cache Module Replacement
Procedures for Array Controller Software V8.7x-x Release Notes
Removing an HSG60 or HSG80 Controller in Dual-Redundant Configurations
Perform the following steps to remove a controller in a dual-redundant controller
configuration.
1. If the controller to be replaced () is functional, complete the following
substeps. Otherwise, go to step 2 below.
a. Connect a PC or terminal to the maintenance port of the controller.
b. Press Enter or Return 2 or 3 times to display the controller prompt.
c. Start the Virtual Terminal Display (VTDPY) Utility by entering the
following command:
RUN VTDPY
d. Record which units have I/O activity.
e. Exit VTDPY by pressing Ctrl+Y.
f. Restart the controller by entering the following command:
RESTART THIS_CONTROLLER
Note: Restarting the controller ensures that the unit persistent reservation flags transfer
to the operational controller.
g. Disconnect the PC or terminal from the maintenance port.
2. For the operational controller (), complete the following substeps:
a. Connect a PC or terminal to the maintenance port of the operational
controller (see Figure 4 on page 15).
Note: The controller connected to the PC or terminal becomes “this controller.” The
controller being removed becomes the “other controller.
b. Set the terminal baud rate to match the controller baud rate, and then press
Enter or Return 2 to 3 times to display the controller prompt.
c. Display and note configuration information (for example, the Failover
mode, Cache mode, serial numbers, SCSI mode, and so forth) for the
operational controller by entering the following command:
SHOW THIS_CONTROLLER