HSG60 and HSG80 Controller and HSx80 Cache Module Replacement Procedures for Array Controller Software V8.7x-x Release Notes

Replacing HSG60 and HSG80 Controllers in Single and Dual-Redundant Controller Configurations
20 HP StorageWorks HSG60 and HSG80 Controller and HSx80 Cache Module Replacement
Procedures for Array Controller Software V8.7x-x Release Notes
16. Disconnect the PC or terminal from the controller maintenance port.
17. Install the program card ESD cover (see Figure 6 on page 17).
Replacing HSG60 and HSG80 Controllers in Dual-Redundant Controller
Configurations
Follow the instructions in this subsection to remove or replace an HSG60 or
HSG80 controller in a dual-redundant controller configuration.
Caution: With ACS V8.7, V8.7-1, and V8.7-2,
FRUTIL
allows you to install
both the controller and cache module in the same process. HP does not
recommend this. Replacing both the controller and cache module at the same
time can result in loss of controller configuration information and will render
the controller unusable.
Note: With ACS V8.7-3,
FRUTIL
prohibits you from installing both the controller and
cache module in one process.
Caution: Electrostatic discharge (ESD) can easily damage the controller. Wear
a snug-fitting, grounded ESD wrist strap when completing controller removal
and installation procedures.
To differentiate on which controller activity is being completed, symbols are
displayed in the margin of text for your convenience. Table 2 describes those
symbols.
Table 2: Replacement Procedure Symbols
Symbol Description
Indicates that the procedural step must be completed for the
operational
controller,
which is
not
being replaced.
Indicates that the procedural step must be completed for the
controller or cache module
that has failed or is to be replaced
.
H
Indicates that the procedural step must be completed for the
field replaceable unit
(FRU), new or replacement controller, or new or replacement cache module being
installed
.