HSG60 and HSG80 Controller and HSx80 Cache Module Replacement Procedures for Array Controller Software V8.7x-x Release Notes
Replacing HSG60 and HSG80 Controllers in Single and Dual-Redundant Controller Configurations
19HP StorageWorks HSG60 and HSG80 Controller and HSx80 Cache Module Replacement
Procedures for Array Controller Software V8.7x-x Release Notes
8. Display details about the configured controller by entering the following
command:
SHOW THIS_CONTROLLER FULL
9. Determine whether the cache is good, and then perform one of the following
options:
■ Refer to Table 3 through Table 5, as applicable, if the cache is not good.
■ Proceed to the next step if the cache is good.
10. Configure the controller as described in the appropriate array controller user
guide or CLI reference guide.
11. Determine whether the current device configuration is saved on a disk drive,
and then perform one of the following options:
■ Manually restore the current device configuration using existing
information and the appropriate array controller user guide or CLI
reference guide if the current device configuration is not saved on a disk
drive.
■ Automatically restore the configuration by entering the following
command below if the current device configuration is saved on a disk
drive:
CONFIGURATION RESTORE
12. Determine whether configuration restore process completed successfully, and
then perform one of the following options:
■ Perform the following substeps if the configuration restore process did
not complete successfully.
a. Reset the PC or terminal baud rate to match the original configuration
of the controller.
b. Repeat step 9 and step 10.
c. Proceed to the next step after a successful configuration.
■ Proceed to the next step if the configuration restore process completed
successfully.
13. Connect all host bus cables or terminators to the controller.
14. Mount the logical units on the host.
15. Restart the server if you are using Windows NT or Windows 2000.