HSG60 and HSG80 Controller and HSx80 Cache Module Replacement Procedures for Array Controller Software V8.7x-x Release Notes

Replacing HSG60 and HSG80 Controllers in Single and Dual-Redundant Controller Configurations
18 HP StorageWorks HSG60 and HSG80 Controller and HSx80 Cache Module Replacement
Procedures for Array Controller Software V8.7x-x Release Notes
Installing a Controller in Single Controller Configurations
Perform the following steps to install a controller in a single controller
configuration.
Caution: Carefully align the controller in the appropriate guide rails.
Misalignment could damage the backplane.
Note: Ensure that the program card is not installed in the controller.
1. Insert the replacement controller into Controller A bay and engage the
retaining levers.
2. Connect a PC or terminal to the controller maintenance port.
3. Press and hold the Reset button while inserting the program card into the
controller.
4. Without releasing Reset button, press and hold the Port #5 button on the
controller.
5. Release the Reset button.
The controller resets its internal configuration cache and halts with an OCP
code 33. LEDs 6, 5, 2, and 1, and the Reset button LED light up.
For ACS V8.7, V8.7-1, and V8.7-2, the controller resets its baud rate to
19200.
For ACS V8.7-3, the controller resets its baud rate to 9600.
6. Release the Port #5 button.
7. Press and release the Reset button.
The controller restarts. This process may take up to three minutes.
Note: Perform the following steps if the controller did not restart:
1. Press and hold the R
RR
Reset
eseteset
eset button.
2. Reseat the controller program card.
3. Release the Reset
ResetReset
Reset button.