HSG60 and HSG80 Controller and HSx80 Cache Module Replacement Procedures for Array Controller Software V8.7x-x Release Notes
Replacing HSG60 and HSG80 Controllers in Single and Dual-Redundant Controller Configurations
17HP StorageWorks HSG60 and HSG80 Controller and HSx80 Cache Module Replacement
Procedures for Array Controller Software V8.7x-x Release Notes
Figure 6: Removing the controller ESD cover
8. Disconnect all host bus cables or terminators from the controller.
Note: Use thin needle nose pliers to disconnect the cables if the extender clips are not
installed on the optical cables.
9. If connected, disconnect the PC or terminal from the controller maintenance
port.
10. Disengage both retaining levers (see Figure 7
), remove the controller, and
then place the controller in an antistatic bag or on a grounded antistatic mat.
Figure 7: Disengaging the controller retaining levers (dual-redundant configuration
shown)
1 Program card slot Eject
button
1 Controller A
2 Controller B
3 Controller retaining
levers
1
1
2
3