HSG60 and HSG80 Controller and HSx80 Cache Module Replacement Procedures for Array Controller Software V8.7x-x Release Notes

Replacing HSG60 and HSG80 Controllers in Single and Dual-Redundant Controller Configurations
16 HP StorageWorks HSG60 and HSG80 Controller and HSx80 Cache Module Replacement
Procedures for Array Controller Software V8.7x-x Release Notes
6. Shut down “this controller” with the following command:
SHUTDOWN THIS_CONTROLLER
Note: After the controller shuts down, the R
RR
Reset
eseteset
eset button and the first three LEDs turn on
(see Figure 5). This might take several minutes to occur, depending on the amount of
data that needs to be flushed from the cache module. Proceed only after the Reset
ResetReset
Reset
button stops flashing and remains on.
Figure 5: [Controller LEDs and Reset button
Caution: The cache module might contain unwritten data if the controller
crashes and it is not shut down with the SHUTDOWN THIS_CONTROLLER
command. Loss of data could occur.
7. Remove the program card ESD cover (see Figure 6) and the program card,
and save them in an antistatic bag or on a grounded antistatic mat for the
replacement controller.
1 Controller Reset button 2 Port LEDs 1 through 6 (consecutively)
123456
2
1