HSG60 and HSG80 Controller and HSx80 Cache Module Replacement Procedures for Array Controller Software V8.7x-x Release Notes

Replacing HSG60 and HSG80 Controllers in Single and Dual-Redundant Controller Configurations
15HP StorageWorks HSG60 and HSG80 Controller and HSx80 Cache Module Replacement
Procedures for Array Controller Software V8.7x-x Release Notes
Figure 4: Connecting PC and terminal cables to the controller maintenance port
(dual-redundant configuration shown)
2. From the host console, halt all host activity to the controller, and dismount the
logical units in the subsystem.
3. If you are using Microsoft
® Windows® NT® or Windows 2000, shut down
the server.
4. Run the Fault Management Utility (FMU) to obtain the last failure codes, if
necessary.
5. Determine whether the disk was initialized with the
SAVE_CONFIGURATION switch, and then perform one of the following
options:
Locate existing information that will support the manual configuration of
the subsystem, and then proceed to step 6 if the disk was not initialized
with the SAVE_CONFIGURATION switch.
Enter the following Command Line Interpreter (CLI) command from the
controller prompt to save the current device configuration for “this
controller” if the disk was initialized with the SAVE_CONFIGURATION
switch:
CONFIGURATION SAVE