HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Utilities and Exercisers
79HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
Figure 12: SHOW DEVICE_INFO ALL sample output
FMU> show device_info all
FL – Device Flags:
Sum of: 1 = Advanced support; 2 = Fairness Support
SC - Save Configuration info:
Not present, Used, Ignored, Disabled
FMU>
P T Model FW Vers S/N on Media FL Metadata
vers/SC
06 04 RZ1BB-CS (C)
DEC
0844 JEC8849802LX5T 0 9/D
02 01 AD009322C5 A019 93078715 0008 0 11/N
02 04 BD018635C4 B012 79003718 0017 3 9/I
06 01 RZ1BB-CS (C)
DEC
0844 JEC8825208T40G 0 11/U
06 03 RZ1BB-CS (C)
DEC
0844 JEC880890KC33W 0 11/U
06 05 RZ1BB-CS (C)
DEC
0844 JEC883640KC37H 0 11/U