HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Troubleshooting Information
54 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
Figure 6: Sample Device Discovery Error Report
Table 10 explains the DWD Status Codes.
1 Test unit ready or read capacity command
failed (refer to Table 48 on page 162).
2 SCSI OpCode, where
00
represents the
OpCode.
3 Sense key, where
04
represents the sense
key.
4 Device work descriptor (DWD) status (see
Table 10 on page 54).
5 DWD Error Codes (see Table 11 on
page 56).
Table 10: DWD Status Codes
Code Description
0x00 Worked.
0x01 Compare operation failed.
0x02 VA must re-do entire XOR.
0x03 VA must re-do XOR for transfer for one or more buffers.
0x04 Drive is not responding properly.
0x05 DWD was aborted.
0x06 Tape has a serious exception.
0x07 Tape position was lost.
0x08 Cache data lost.
%EVL--hsg80_bot> --08-JUN-2004 11:37:26-- Instance Code: 03D04002
Template: 65.(41)
Occurred on 08-JUN-2004 at 11:37:11
Power On Time: 2. Years, 79. Days, 13. Hours, 34. Minutes, 26. Second
s
Controller Model: HSG80
Serial Number: ZG95114377 Hardware Version: E11(29)
Software Version: V88F-0(FF)
Port: 1. Target: 3.
ASC: (3F) ASCQ: (85)
OP|KEY: x0004 ST: x17 EC: 9.
4
5
2
1
3