HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Troubleshooting Information
34 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
Solid OCP pattern display reporting
Certain events cause the OCP LEDs to display on or solid. Each event and the
resulting pattern are described in Table 6 on page 35.
Information related to the solid OCP patterns is automatically displayed on the
maintenance terminal (unless disabled with the FMU) and use %FLL formatting
(see Figure 1).
Figure 1: OCP pattern display showing %FLL formatting
nllllmm 3C An unexpected fault
occurred during
initialization.
Replace controller.
nllllml 3D An unexpected maskable
interrupt occurred
during initialization.
Replace controller.
nlllllm 3E An unexpected NMI
occurred during
initialization.
Replace controller.
nllllll 3F An invalid process ran
during initialization.
Replace controller.
Table 5: Flashing OCP Pattern Displays and Repair Actions (Continued)
Pattern
OCP
Code
Error Repair Action
%FLL--HSG> --13-MAY-2004 04:39:45 (time not set)-- OCP Code: 38
Controller operation terminated.
%FLL--HSG> --13-MAY-2004 04:32:26 (time not set)-- OCP Code: 26
Memory module is missing.