HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Last Failure Codes
257HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
12080102 VSI_PTR->CS_INTERLOCKED not set:
Last failure parameter [0] contains the ASSUME instance address.
Last failure parameter [1] contains NV_INDEX value.
01
12090102 Unhandled switch case:
Last failure parameter [0] contains the ASSUME instance address.
Last failure parameter [1] contains NV_INDEX value.
01
120A0103 WARP expand point value does not match blocks:
Last failure parameter [0] contains the WARP address.
Last failure parameter [1] contains the WARP expand point value.
Last failure parameter [2] contains the WARP blocks value.
01
120B2380 Forced restart of the controller upon a cache battery failure. This is done
only under conditions that require the restart for error recovery.
23
120C0101 Found invalid UPS Descriptor state:
Last failure parameter[0] contains UPS Descriptor state.
01
120D0100 Initialization code was unable to allocate enough memory to set up the
send data descriptors for local buffer transfers.
01
120E0310 An image upgrade that updated the cache metadata version failed
because the cache module hardware for non-volatile metadata
contained therein was bad. Either “this controller” cache hardware
failed (or for the case of mirrored cache, the “other controller” cache
hardware), or the cache metadata was in an Invalid state. Restart “this
controller” with the pre-upgrade image, and issue the
SHOW THIS_CONTROLLER CLI command to determine whether the
hardware failed or the metadata was in the Invalid Cache state. Fix the
condition and verify that it is fixed before restarting the upgrade
procedure from the beginning.
03
120F0310 An image upgrade that updated the cache metadata version failed
because the cache module holds dirty data that needs to be flushed prior
to image swap. Restart “this controller” with the pre-upgrade image, and
restart the upgrade procedure from the beginning. This procedure
causes dirty data to be flushed before the new image is installed.
03
Table 56: Last Failure Codes and Repair Action Codes (Sheet 44 of 55)
Last
Failure
Code
Description
Repair
Action
Code