HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Last Failure Codes
243HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
03530102 A DWD with an illegal address was found:
Last failure parameter [0] contains the bad DWD pointer.
Last failure parameter [1] contains the corresponding PCB pointer.
01
035A0100 Invalid SCSI message byte passed to DS. 01
035B0100 Insufficient DWD resources available for SCSI message passthrough. 01
03640100 Processing RUN_SWITCH disabled for LOGDISK associated with the
“other controller.”
01
03650100 Processing PUB unblock for LOGDISK associated with the “other
controller.”
01
03660100 No memory available to allocate PUB to tell the “other controller” of reset
to one if its LUNs.
01
03670100 Changes to a Bad Block Replacement (BBR) occurred. 01
036F0101 Either SEND_SDTR or SEND_WDTR flag set in a non-miscellaneous
DWD:
Last failure parameter [0] contains the invalid command class type.
01
03780181 In DS_GET_RESUME_ADDR, the buffer address is non-longword aligned
for FX access:
Last failure parameter [0] contains the re-entry bad address value.
01
Table 56: Last Failure Codes and Repair Action Codes (Sheet 30 of 55)
Last
Failure
Code
Description
Repair
Action
Code