HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Last Failure Codes
242 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
03450188 A Master Data Parity Error was detected by a port:
Last failure parameter [0] contains the PCB PORT_PTR value.
Last failure parameter [1] contains the PCB copies of the device port
DCMD/DBC registers.
Last failure parameter [2] contains the PCB copy of the device port
DNAD register.
Last failure parameter [3] contains the PCB copy of the device port DSP
register.
Last failure parameter [4] contains the PCB copy of the device port DSPS
register.
Last failure parameter [5] contains the PCB copies of the device port
DSTAT/SSTAT0/SSTAT1/SSTAT2 registers.
Last failure parameter [6] contains the PCB copies of the device port
DFIFO/ISTAT/SBCL/RESERVED registers.
Last failure parameter [7] contains the PCB copies of the device port
SIST0/SIST1/SXFER/SCNTL3 registers.
01
03470100 Insufficient memory available for target block allocation. 01
03480100 Insufficient memory available for device port info block allocation. 01
03490100 Insufficient memory available for automatic configuration buffer
allocation.
01
034A0100 Insufficient memory available for PUB allocation. 01
034B0100 (No description) 01
034C0100 Insufficient memory available for static structure allocation. 01
034D0100 DS init DWDs exhausted. 01
034E2080 Diagnostics report all device ports are broken. 20
034F0100 Insufficient memory available for reselect target block allocation. 01
03500100 Insufficient memory available for command disk allocation. 01
03520100 A failure resulted after an attempt was made to allocate a DWD for use
by DS Command Data Interface (CDI).
01
Table 56: Last Failure Codes and Repair Action Codes (Sheet 29 of 55)
Last
Failure
Code
Description
Repair
Action
Code