HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Last Failure Codes
235HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
030B0188 A dip error was detected after PCB_BUSY was set:
Last failure parameter [0] contains the Process Controls Block (PCB)
PORT_PTR value.
Last failure parameter [1] contains the new info
NULL-SSTAT0-DSTAT-ISTAT.
Last failure parameter [2] contains the PCB copy of the device port DMA
Byte Counter (DBC) register.
Last failure parameter [3] contains the PCB copy of the device port DMA
Next Address Data (DNAD) register.
Last failure parameter [4] contains the PCB copy of the device port DMA
SCRIPTS Pointer (DSP) register.
Last failure parameter [5] contains the PCB copy of the device port DMA
SCRIPTS Pointer Saved (DSPS) register.
Last failure parameter [6] contains the PCB copies of the device port
SSTAT2/SSTAT1/SSTAT0/DSTAT registers.
Last failure parameter [7] contains the PCB copies of the device port
LCRC/RESERVED/ISTAT/DFIFO registers.
01
031E0100 Cannot find IN_ERROR DWD on in-process queue. 01
031F0100 Either DWD_PTR is NULL or bad value in dsps. 01
03280100 SCSI CDB contains an invalid group code for a transfer command. 01
03290100 The required Event Information Packet (EIP) or DWD were not supplied to
the Device Services error logging code.
01
032B0100 A DWD was supplied with a NULL PUB pointer. 01
03320101 An invalid code was passed to the error recovery thread in the
ERROR_STAT field of the PCB:
Last failure parameter [0] contains the PCB ERROR_STAT code.
01
Table 56: Last Failure Codes and Repair Action Codes (Sheet 22 of 55)
Last
Failure
Code
Description
Repair
Action
Code