HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Last Failure Codes
222 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
01960186
The IBUS is inaccessible:
Last failure parameter [0] contains the value of read diagnostic register 0.
Last failure parameter [1] contains the value of read diagnostic register 1.
Last failure parameter [2] contains the value of read diagnostic register 2.
Last failure parameter [3] contains the value of write diagnostic register 0.
Last failure parameter [4] contains the value of write diagnostic register 1.
Last failure parameter [5] contains the IBUS address of the error register.
01
01970188
Software indicates all NMI causes cleared, but some remain:
Last failure parameter [0] contains the value of read diagnostic register 0.
Last failure parameter [1] contains the value of read diagnostic register 1.
Last failure parameter [2] contains the value of read diagnostic register 2.
Last failure parameter [3] contains the value of write diagnostic register 0.
Last failure parameter [4] contains the value of write diagnostic register 1.
Last failure parameter [5] contains the IBUS address of the error register.
Last failure parameter [6] contains the PCFX PDAL control and status
register.
Last failure parameter [7] contains the PCFX CDAL control and status
register.
01
01982087
The IBUS encountered a parity error:
Last failure parameter [0] contains the value of read diagnostic register 0.
Last failure parameter [1] contains the value of read diagnostic register 1.
Last failure parameter [2] contains the value of read diagnostic register 2.
Last failure parameter [3] contains the value of write diagnostic register 0.
Last failure parameter [4] contains the value of write diagnostic register 1.
Last failure parameter [5] contains the IBUS address of the error register.
Last failure parameter [6] contains the RIP.
20
Table 56: Last Failure Codes and Repair Action Codes (Sheet 9 of 55)
Last
Failure
Code
Description
Repair
Action
Code