HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Last Failure Codes
215HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
01030100 Memory allocation for a facility lock failed. 01
01040100 Memory initialization called with invalid memory type. 01
01082004 The core diagnostics reported a fault:
Last failure parameter [0] contains the error code value (same as flashing
OCP LEDs error code).
Last failure parameter [1] contains the address of the fault.
Last failure parameter [2] contains the actual data value.
Last failure parameter [3] contains the expected data value.
20
01090105 A non-maskable interrupt (NMI) occurred during EXEC$BUGCHECK
processing:
Last failure parameter [0] contains the executive flags value.
Last failure parameter [1] contains the Return Instruction Pointer (RIP)
from the NMI stack.
Last failure parameter [2] contains the read diagnostic register 0 value.
Last failure parameter [3] contains the FX Chip Control and Status
Register (CSR) value.
Last failure parameter [4] contains the System Information Page (SIP) LFC
value.
01
010D0110 The System Information structure within the SIP was reset to default
settings. The only known cause for this event is an Intel i960 processor
hang caused by a reference to a memory region that is not implemented.
After this occurs, controller modules equipped with an inactivity
watchdog timer circuitry spontaneously reboots after the watchdog timer
expires (within seconds of the hang). Controller modules not so equipped
hang as indicated by the green LED on the OCP remaining in a Steady
state.
01
010E0110 All structures contained in the SIP and the Last Failure entries have been
reset to their default settings. This is a normal occurrence for the first
power on following manufacture of the controller module and during the
transition from one software version to another if the format of the SIP is
different between the two versions. If this event is reported at any other
time, follow the recommended Repair Action associated with this LFC.
01
Table 56: Last Failure Codes and Repair Action Codes (Sheet 2 of 55)
Last
Failure
Code
Description
Repair
Action