HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Last Failure Codes
214 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
Hardware and software flag
The hardware and software (HW) flag is located at byte offset 104, bit 7. If this
flag is a 1, the unrecoverable condition is due to a hardware detected fault. If this
flag is a 0, the unrecoverable condition is due to an inconsistency with the
software, or a requested restart or shutdown of the controller.
Repair Action Code
The Repair Action Code at byte offset 105 indicates the recommended Repair
Action Code assigned to the failure. This value is used during symptom-directed
diagnosis procedures to determine what notification and recovery action to take.
For details about recommended Repair Action Codes, see Table 49 on page 167.
Error Number
The Error Number is located at byte offset 106. Combining this number with the
Component ID field value uniquely identifies the reported failure.
Component ID Code
The Component ID Code is located at byte offset 107. This code uniquely
identifies the software component that reported the failure. For details about
component ID codes, see the “ASC, ASCQ, Repair Action, and Component
Identifier Codes’ chapter that starts on page 161.
Last Failure and Repair Action Codes
Table 56 lists Last Failure Codes that are issued from the controller. Codes are
listed in ascending order.
Table 56: Last Failure Codes and Repair Action Codes (Sheet 1 of 55)
Last
Failure
Code
Description
Repair
Action
Code
01000100 Memory allocation failure during executive initialization. 01
01010100 An interrupt without any handler was triggered. 01
01020100 Entry on timer queue was not of type Associated Queue (AQ) or
Blocking Queue (BQ).
01