HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Instance Codes
186 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
024B2401 Writeback caching is disabled either due to a cache
or battery-related problem. The exact nature of the
problem is reported by other Instance Codes. In this
instance, the Memory Address, Byte Count, FX Chip
Register, Memory Controller Register, and Diagnostic
Register fields are undefined.
14 24
024F2401 This cache module is populated with DIMMs
incorrectly. Cache metadata resident in the cache
module indicates that unflushed write cache data
exists for a cache size different than what is found
present. In this instance, the Memory Address, Byte
Count, FX Chip Register, Memory Controller Register,
and Diagnostic Register fields are undefined.
14 24
0251000A This command failed because the target unit is not
online to the controller. The Information field of the
device sense data contains the block number of the
first block in error.
51 00
0253000A The data supplied from the host for a data compare
operation differs from the data on the disk in the
specified block. The Information field of the device
sense data contains the block number of the first block
in error.
51 00
0254000A The command failed due to a host data transfer
failure. The Information field of the device sense data
contains the block number of the first block in error.
51 00
0255000A The controller was unable to successfully transfer data
to the target unit. The Information field of the device
sense data contains the block number of the first block
in error.
51 00
0256000A The write operation failed because the unit is data
safety write-protected. The Information field of the
device sense data contains the block number of the
first block in error.
51 00
Table 53: Instance Codes and Repair Action Codes (Sheet 6 of 30)
Instance
Code
Description Template
Repair
Action
Code