HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

ASC, ASCQ, Repair Action, and Component Identifier Codes
173HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
83 An EMU is unavailable.
This EMU (and associated cabinet) may have been removed from the subsystem;
no action is required.
The cabinet has lost power. Restore power to the cabinet.
The EMU-to-EMU communications bus cable is disconnected or broken. Replace or
reconnect the cable to reestablish communications.
The specified EMU is broken. Replace the EMU module.
The EMU in cabinet 0 is broken. Replace the EMU module.
88 The remote copy set has an online initiator unit and at least one remote Normal or
Normalizing target member. Failsafe error mode can now be enabled by entering the
following CLI command:
SET remote-copy-set-name ERROR_MODE=FAILSAFE
89 The remote copy set is inoperative due to a disaster tolerance failsafe locked condition
resulting from the loss of the local initiator unit or remote Normal or Normalizing target
members while ERROR_MODE=FAILSAFE was enabled. To clear the failsafe locked
condition, enter the following CLI command:
SET remote-copy-set-name ERROR_MODE=NORMAL
8A The indicated remote copy set target member was removed for one of the following
reasons:
By operator command.
The member malfunctioned. Perform the repair actions indicated in any and all
event reports found for that target member.
8B Unable to communicate to the target member of the remote copy set for one of the
following reasons:
The target malfunctioned. Perform the repair actions indicated in any and all event
reports found for that target unit.
The target controller malfunctioned. Perform the repair actions indicated in any
and all event reports found for that target controller.
Malfunction occurred in the Fibre Channel fabric between the peer controllers.
8C Unable to communicate to an initiator unit of the remote copy set because the unit
malfunctioned. Perform the repair actions indicated in any and all event reports found
for that initiator unit.
Table 49: Recommended Repair Action Codes (Sheet 7 of 8)
Code Description