HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

ASC, ASCQ, Repair Action, and Component Identifier Codes
162 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
Vendor-specific SCSI ASC and ASCQ codes
Table 48 lists HSG60 and HSG80 controller vendor-specific SCSI ASC and
ASCQ codes. These codes are also template-specific and appear at byte offsets 12
and 13.
Note: Additional codes that are common to all SCSI devices can be found in the
Small
Computer System Interface-2 (SCSI-2)
specification.
.
Table 48: ASC and ASCQ Code Descriptions (Sheet 1 of 5)
ASC
Code
ASCQ
Code
Description
04 80 Logical unit is disaster tolerant failsafe locked
(inoperative).
3F 85 Test unit ready or read capacity command failed (see the
Device Discovery Error report” section that starts on
page 53).
3F 87 Drive failed by a host mode select command.
3F 88 Drive failed due to a deferred error reported by drive.
3F 90 Unrecovered read or write error.
3F C0 No response from one or more drives.
3F C2 NV memory and drive metadata indicate conflicting drive
configurations.
3F CE UPS two-minute warning (TMW) before AC_FAIL.
3F D2 Synchronous transfer value differences between drives.
80 00 Forced error on read.
82 01 No command control structures available.
84 04 Command failedSCSI ID verification failed.
85 05 Data returned from drive is invalid.
89 00 Request sense command to drive failed.
8A 00 Illegal command for Passthrough mode.
8C 04 Data transfer request error.
8F 00 Premature completion of a drive command.