HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Event Reporting Templates
153HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
Device Services Nontransfer Error Event Sense Data Response
template (Template 41)
The controller device services software component reports errors detected while
performing nontransfer work-related functions to disk (including CD-ROM and
optical memory) device operations through the Device Services Nontransfer
Event Sense Data Response (see Table 45). If an error occurred during the
execution of a command issued by an HSG60 and
HSG80 controller software
component, it is signaled to all host systems on all logical units.
■ ASC and ASCQ codes (byte offsets 12 and 13) are detailed in the “ASC,
ASCQ, Repair Action, and Component Identifier Codes” chapter that starts
on page 161.
■ Instance Codes (byte offsets 32–35) are detailed in the “Instance Codes”
chapter that starts on page 177.
Table 45: Template 41—Device Services Non-Transfer Error Event Sense Data
Response Format
↓
offset
bit
→
7 6 5 4 3 2 1 0
0Unused Error code
1Unused
2Unused Sense key
3–6 Unused
7 Additional sense length
8–11 Unused
12 ASC
13 ASCQ
14 Unused
15–17 Unused
18–31 Reserved
32–35 Instance Code
36 Template
37 Template flags
38–53 Reserved
54–69 Controller board serial number
70–73 Controller software revision level
74 Reserved or patch version (TM2)