HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Utilities and Exercisers
120 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
3. Run DILX with the following command:
RUN DILX
The system displays the following prompt: It is recommended that
DILX only be run when there is no host activity
present on the controller. Do you want to continue
(y/n)[n]?
4. Enter Y(es) to accept.
Note: Use the auto configure option to test the read and write capabilities of every
unit in the subsystem.
5. Enter N(o) to decline the auto configure option and to allow testing of a
specific unit.
6. Enter Y(es) to accept the default test settings and to run the test in read-only
mode.
7. Enter the unit number of the specific unit to test (for example, to test D107,
enter the number 107).
8. To test more than one unit, enter the appropriate unit numbers after prompted.
Otherwise, enter N(o) to start the test.
Note: Use the control sequences listed in Table 33 to control
DILX
during the test.
Table 33: DILX Control Sequences
Command Action
Ctrl+C Stops the test.
Ctrl+G Displays the performance summary for the current test and
continues testing.
Ctrl+Y Stops the test and exits
DILX
.