User Manual - A3661-90001

6-48 Unsolicited Event Log
Bound but Unassigned Problems
3UREOHPVRFFXULIGLVNPRGXOHVDUHPRYHGWRGLIIHUHQWVORWVRUWRGLIIHUHQWDUUD\VDIWHUEHLQJ
ERXQGVRWKDWWKH\DUHRXWRIRUGHU,IWKLVLVGRQHLQPRVWFDVHVWKHGDWDRQWKHGLVNPRGXOHVLV
GHVWUR\HG7KHW\SLFDOIDLOXUHRFFXUVDVIROORZV
 7KHGLVNPRGXOHVDUHERXQGLQWR/81VHLWKHUDWRUDIWHULQLWLDOLQVWDOODWLRQ
 'LVNPRGXOHVDUHPRYHGIURPRQHGLVNDUUD\WRDQRWKHURUIURPRQHVORWWRDQRWKHU
 7KHGLVNPRGXOHVDUHXVXDOO\PRYHGZKLOHSRZHULVRIIEXWVRPHWLPHVZKLOHSRZHULVRQ
Table 6-11 Fatal Error Codes
Event
code Event code name Description
0xA02 Failed SCSI Bus An internal SCSI bus failed and all disk modules on that bus
are inaccessible by the SP. The CRU number displayed
corresponds to the bus number. The failure resulted from a
bad cable or cable connection, bad terminator, bad SCSI chip
on an SP or a bad device.
0xA05 NOVRAM Uninitialized The nonvolatile memory on this SP is uninitialized. The SP
has reinitialized the memory to its default state, but the SP
must be rebooted to be operational.
0xA06 Chassis Shutdown An overtemperature situation could not be corrected. All disk
modules in the chassis will be shut down. The problem must
be corrected before powering up again.
0xA07 Drive Failure The disk drive has failed and can no longer be accessed.
0xA08 Data Base Sync Error The SP cannot determine the correct logical configuration of
all units in this disk array. Some units may be unusable.
0xA09 Drive Too Small A replacement drive, which does not have adequate capacity
for a rebuild operation to begin, has been inserted.
0xA11 Peer Controller Removed This SP's peer is no longer responding to this SP’s queries
following a period of time when the peer was known present.
0xA12 Cache Memory Hard
Error
This SP, which is operating in nonmirrored caching mode, has
detected an unrecoverable memory fault in its cache memory
area. This error does not apply to a disk array with two SPs.
0xA13 CRU Type Unsupported This type of disk module is not supported by the SP
microcode. The disk module cannot be bound or used for host
I/Os.