User Manual - A3661-90001

5-18 Support Tools Manager (STM)
Selected Expert Tool Screens
7KHIROORZLQJVFUHHQFDSWXUHV)LJXUHWKURXJKDUHH[DPSOHVRIVHOHFWHG([SHUW7RRO
VFUHHQV
Utilities
Bind LUN N/A Binds selected disk modules into a LUN
with a specified RAID level.
Unbind LUNs N/A Unbinds a LUN.
Lun Configuration
Auto-assign Enables or disables the auto-assign state of
a LUN.
Cache Parms Enables or disables write and read caching
for a LUN.
Default SP Sets the default SP for a specified LUN.
Rebuild Time Sets the maximum amount of time the disk
array should take to rebuild a failed disk
module on a LUN.
System Configuration
Auto-Trespass Sets the auto-trespass state on or off.
BBU Test Time Specifies the day and time the BBU self-test
is to be executed.
Date Time Sets disk array date and time to match the
host system.
Host I/F Options Sets or changes the Host interface settings
for the selected disk array. See Figure 5-22.
Serial Number Sets or changes the disk array’s serial
number.
System Cache Specifies system cache states. See Figure
5-23.
System Memory Specifies system memory configuration
values. See Figure 5-24.
System Type Controls certain operating characteristics of
the array. HP-supported types are 2 and A.
Table 5-7 Expert Tool Menus and Descriptions (Continued)
Menu
Items Option Property Description