User Guide

6XSSRUW7RROV0DQDJHU670 7-25
Host Utilities and
Diagnostics
6HOHFWHG([S HUW 7RRO 6FUHHQV
7KHIROORZLQJVFUHHQFDSWXUHV)LJXUHWKURXJK)LJXUHDUHH[DPSOHVRIVHOHFWHG
([SHUW7RROVFUHHQV
Utilities Bind LUN N/A Binds selected disk modules into a LUN
with a specified RAID level.
Unbind LUNs N/A Unbinds a LUN.
LUN Configuration Auto-assign Enables or disables the auto-assign state of
a LUN.
Cache Parms Enables or disables write and read caching
for a LUN.
Default SP Sets the default SP for a specified LUN.
Rebuild Time Sets the maximum amount of time the SCSI
disk array should take to rebuild a failed
disk module on a LUN.
System Configuration Auto-Trespass Sets the auto-trespass state on or off.
BBU Test Time Specifies the day and time the BBU self-test
is to run.
Date Time Sets SCSI disk array date and time to
match the host system.
Host I/F Options Sets or changes the Host interface settings
for the selected SCSI disk array. See Figure
7-24.
Serial Number Sets or changes the disk array’s serial
number.
System Cache Specifies system cache states. See Figure
7-22.
System Memory Specifies system memory configuration
values. See Figure 7-23.
System Type Controls certain operating characteristics of
the array. HP-supported types are 2 and A.
7DEOH ([SHUW7RRO0HQXVDQG'HVFULSWLRQVFRQWªG
Menu
items Option Property Description