User Guide

&KDQJLQJ6WRUDJH6\VWHP3DUDPHWHUV 6-59
Grid Manager
Changing Storage System Parameters
6LJQLILFDQWSUREOHPVZLOORFFXULIWKH63SDUDPHWHUVDUHFKDQJHGLQWKH+RVW,QWHUIDFH
2SWLRQVDUHD7KHKRVWLQWHUIDFHRSWLRQVPXVWQHYHUEHFKDQJHGLQGLYLGXDOO\7KHRSWLRQV
DUHSURSHUO\VHWE\VHOHFWLQJHLWKHU6WRUDJH6\VWHP2SWLRQ3DFNDJH$RU7KHGHIDXOW
VHWWLQJIRUWKHILUVWLWHPLQWKHKRVWLQWHUIDFHRSWLRQV$GGUHVVLQJPRGHOLV/81YDOXH
3UREOHPVRFFXULIWKLVYDOXHLVFKDQJHGWR7$5*(7
:KHQWKH$GGUHVVLQJPRGHOLVVHWWR7$5*(7WKH6&6,DGGUHVVVZLWFKHVDUHE\SDVVHG
7KHUHVXOWLVWKDWWKHDGGUHVVVZLWFKHVKDYHQRHIIHFWRQZKDWLVVHHQE\WKHKRVWV\VWHP
RU(0WHUPLQDOFRQQHFWLRQ)RUH[DPSOHLIWKH)DVW:LGH6&6,KRVWDGDSWHU
+3 $LVDWKDUGZDUHDGGUHVVDQGWKH6&6,DGGUHVVLVVHWWRDQGDQG/81V
DUHERXQGDWDQGDQG7$5*(7PRGHOJHWVVHWLRVFDQDQGDXWRFRQILJVHHWKH
DGGUHVVHVDVDQGUDWKHUWKDQWKHH[SHFWHGHWF,Q
DGGLWLRQWRWKHKRVWV\VWHPVHHLQJLQFRUUHFW6&6,DGGUHVVHVWKH*ULG0DQDJHUVFUHHQ
VKRZVQR6&6,DGGUHVVDVVRFLDWHGZLWKWKH63VHOHFWHGYLD*ULG0DQDJHU
7KHVWRUDJHV\VWHPSDUDPHWHUVFDQEHPRGLILHGRQO\E\DQ+3VHUYLFHUHSUHVHQWDWLYHDQG
VKRXOGEHVHWFRUUHFWO\DWWKHWLPHWKHGLVNDUUD\LVLQVWDOOHG
&KHFNLQJ$XWR7UHVSDVVDQG2SWLRQ3DFNDJH
7KHUHLVQRSODFHWRORRNLQ*ULG0DQDJHUWRGHWHUPLQHZKLFKRSWLRQSDFNDJHKDVEHHQVHW
RQWKHDUUD\IRUPLFURFRGHUHYLVLRQ*ULG0DQDJHULQFOXGHVDILHOGWKDWGLVSOD\VWKH
V\VWHPW\SHIRUPLFURFRGHUHYLVLRQ)RUPLFURFRGHUHYLVLRQDXWRWUHVSDVVRQHRI
WKHSDUDPHWHUVLQWKH6WRUDJH6\VWHPV2SWLRQ3DFNDJHLVRQIRURSWLRQSDFNDJHDQGRII
IRURSWLRQSDFNDJH$,IWKHRSWLRQSDFNDJHLVVHWFRUUHFWO\WKHIROORZLQJH[DPSOHRXWSXW
VKRXOGDSSHDUDIWHUUXQQLQJWKHLRVFDQFRPPDQG
OPTION PACKAGE “A” FOR HP-UX 9.04 (Two SPs in one array with jumper cable installed)
Class LU H/W Path Driver H/W Status S/W Status
disk 0 8.5.0 scsi3.target.disc3 ok (0x20650202 ok
disk 1 8.6.0 scsi3.target.disc3 ok (0x650202 ok
disk 2 8.6.1 scsi3.target.disc3 ok (0x650202) ok
OPTION PACKAGE “2” FOR HP-UX 10.0 (Two SPs in one array with jumper cable installed)
Class I H/W Path Driver S/W State H/W Type Description
disk 0 16.5.0 disc3 CLAIMED DEVICE DGC C2300WDR5