User Guide
%DVLF&RQILJXUDWLRQIRU0RGHO'LVN $UUD\ 3-7
Configuration, HP 9000
Series 700
7DEOH %DVLF&RQILJXUDWLRQ(UURU5HFRYHU\
Failing
component
Continue after
failure? What happens and how to recover
Disk module Yes Applications continue running. System Administrator or
service provider replaces module.
SP No Disk array fails. System Administrator or service provider
replaces SP and the System Administrator restarts
operating system.
Fan failure
within fan pack
Yes Applications continue running. System Administrator or
service provider replaces module.
Power supply Yes If a redundant power supply module is present,
applications continue running; otherwise, disk array fails.
Service provider replaces power supply and System
Administrator restarts operating system, if necessary.
SCSI-2 adapter No I/O operations to array disk units fail. Authorized service
provider replaces adapter and System Administrator
restarts operating system and applications.
SCSI-2 cable No I/O operations to array disk units fail. Authorized service
provider replaces cable and System Administrator
restarts operating system and applications.