FW 07.00.00/HAFM SW 08.06.00 McDATA E/OS SNMP Support Manual (620-000131-620, April 2005)
C
C-50
E/OS SNMP Support Manual
McDATA Private Enterprise MIB
Status mandatory
Description The number of minutes in a threshold alert interval.
Sequence
::= { fcEosTAEntry 7 }
fcEosTATriggerValue
Syntax INTEGER
Access read-only
Status mandatory
Description If the alert type is a Throughput Threshold Alert, then this is the
percent utilization (1-100) required to trigger an alert. If the alert type
is a Counter Threshold Alert, then this is the counter delta required to
trigger an alert.
Sequence
::= { fcEosTAEntry 8 }
fcEosTTADirection
Syntax INTEGER { transmit (1), receive (2), either (3) -- (Tx or Rx) }
Access read-only
Status mandatory
Description This only applies when the alert type is a Throughput Threshold
Alert. It specifies the throughput direction of the threshold.
Sequence
::= { fcEosTAEntry 9 }
fcEosTTATriggerDuration
Syntax INTEGER
Access read-only
Status mandatory
Description This only applies when the alert type is a Throughput Threshold
Alert. It specifies the amount of time during a threshold alert interval
that the trigger must be exceeded before an alert is generated.
Sequence
::= { fcEosTAEntry 10 }