FcConnUnitSensorName
Type SnmpAdminString
Product Mapping The module name of the FRU, such as FAN, PWR or THM
Access R
Description A textual identification of the sensor intended primarily for operator
use.
FcConnUnitSensorStatus
Type INTEGER
Product Mapping This value is evaluated from FRU status. The active, backup and
update-busy states are mapped to ok(3). And the failed state is
mapped to failed(5).
Access R
Description The status indicated by the sensor. The values are defined as
unknown (1) – the unit cannot determine the status, other (2) -- the
status does not fit any of the remaining values, ok (3) – indicates good
status, warning (4) – indicates the unit needs attention, failed (5) B
indicates the unit is non-functional.
FcConnUnitSensorInfo
Type SnmpAdminString
Product Mapping The serial number of the FRUs. It’s not supported if the module is
failed.
Access R
Description Miscellaneous static information about the sensor such as its serial
number.
FcConnUnitSensorMessage
Type SnmpAdminString
Product Mapping The textual description of the FRU status, such as “active” or “failed”.
Access R