Using EMS HA Monitors

28 Chapter 1
Installing and Using EMS
Using EMS HA Monitors
Figure 1-8 Package Resource Dependencies Screen
When you select a resource, either from the “Add a Resource” screen, or from the
“Package Resource Dependencies” screen by selecting a resource and clicking
“Modify Resource Dependencies...” you get a screen similar to Figure 1-9.
To make a package dependent on an EMS resource, select a Resource Up Value
from the list of Available Resource Values, then click “Add.” The example in Figure
1-9 shows the possible values for pv_summary. Different resources show different
available “Up” values.
NOTE Make sure you always select UP as one of the UP values. MC/ServiceGuard creates
an EMS request that sends an event if the resource value is not equal to the UP
value.
If you select UP, the package fails over if the value is anything but UP. If you select
UP and PVG-UP, the package fails over if the pv_summary value is not equal to UP
or PVG_UP; in other words, if pv_summary were SUSPECT or DOWN.
The polling interval determines the maximum amount of elapsed time before the
monitor knows about a change in resource status. For critical resources, you may
want to set a short polling interval, for example 30 seconds, which could adversely
affect system performance. With longer polling intervals you gain system
performance, but risk not detecting problems soon enough.