High Availability Monitors Version A.03.02 Release Notes
NOF API Verbs (QUERY Verbs)
QUERY_3270_DIAG
Chapter 4 491
The number of alert entries actually returned.
diag_3270_data
Data structure containing 3270 diagnostics
information. The format of this information is the same
as for the DEFINE_3270_DIAG verb.
For each alert, up to the number specified in
num_entries
, an
alert_3270_data structure is included. The format ofthe information in
this structure is the same as for the DEFINE_3270_DIAG verb.
Returned Parameters: Parameter Check
If the verb does not execute because of a parameter error, SNAplus2
returns the following parameters:
primary_rc
AP_PARAMETER_CHECK
secondary_rc
Possible values are:
AP_INVALID_ALERT_NUMBER
The
list_options
parameter was set to
AP_LIST_INCLUSIVE or AP_LIST_FROM_NEXT, but
one of the following has occurred:
• The
alert_number
parameter was not in the valid
range.
• The alert with the specified number has not been
defined.
• No alerts have been defined.
AP_INVALID_LIST_OPTION
The
list_options
parameter was not set to a valid
value.
Appendix A, “Common Return Codes,” lists further secondary return
codes associated with AP_PARAMETER_CHECK, which are common to all