High Availability Monitors Version A.03.02 Release Notes
NOF API Verbs (ACTIVATE_SESSION to OPEN_FILE)
DEFINE_PORT
Chapter 3 341
AP_PORT_NONSWITCHED
Nonswitched line.
For QLLC, this parameter must be set to
AP_PORT_SWITCHED.
For Token Ring / Ethernet / FDDI,this parameter must
be set to AP_PORT_SATF (shared access transport
facility).
def_data.port_attributes
This is a one-bit parameter that may take the following
values:
AP_NO
Incoming calls are resolved by CP name.
AP_RESOLVE_BY_LINK_ADDRESS
This specifies that an attempt is made to resolve
incoming calls by using the link address on
CONNECT_IN before using the CP name (or node ID)
carried on the received XID3 to resolve them. This bit
is ignored unless the
port_type
parameter is set to
AP_PORT_SWITCHED.
def_data.port_number
The number of the port.
def_data.max_rcv_btu_size
Maximum BTU size that can be received. The value
includes the length of the TH and RH (total 9 bytes) as
well as the RU. Specify a value in the range 265-65,535
(265-4105 for SDLC).
def_data.tot_link_act_lim
Total link activation limit (the maximum number of
links that can be active at any time using this port).
For an SDLC port with
port_type
set to
AP_NONSWITCHED and
ls_role
set to AP_LS_PRIor
AP_LS_SEC, the range is 1-256 (a value greater than 1
defines a multi-drop primary link or a multi-PU
secondary link). For all other SDLC ports, this